| Indicates incorrect room temperature |
- Refer to thermostat manual to verify that your set temperature is what you expect it to be.
- Refer to your thermostats manual for calibration. Use this feature to adjust the displayed temperature up to +5°F(3°C) or -5°F(3°C) degrees.
|
Heats or cools more than 5 degrees
past its displayed set temperature |
- Verify that the ON/OFF switch on the side of the unit is set to ON.
- Refer to thermostat manual to verify that your set temperature is what you expect it to be.
- Refer to your units manual to decrease the units swing value to a narrower setting.
- Verify that your units placement and mounting are reasonable per the installation section of it's manual.
|
| No heat or cooling when expected. |
- Verify that the ON/OFF switch on the side of the unit is set to ON.
- Refer to thermostat manual to verify that your set temperature is what you expect it to be.
|
| Operational Test |
- Set unit to heat mode. Adjust set temperature to at least 5 degrees below room temperature. Then adjust set temperature upward one degree at a time. Listen carefully for a soft click from the thermostat. This click should be heard near room temperature. Heat should operate immediately.
- Adjust set temperature down one degree at a time. Again listen carefully for a soft click from the thermostat near room temperature. Heat should switch off immediately.
|
| Advanced Trouble Shooting |
- This thermostat is designed to switch hazardous voltage. Qualified service personnel may use the following information to trouble shoot the system.
- The WIN100 uses a normally open single pole relay to control a heating or cooling system.
- In heat mode it should open when hotter than its set temperature and close when cooler than its set temperature.
- In cool mode it should close when hotter than its set temperature and open when cooler than its set temperature.
|
| |
- Contact your HVAC service company or our Technical Assistance
Line if not resolved.
|